Microsoft Word – UOS_HL40071MG_DS_R1.docx
image/svg+xmlData SheeHL40071MG 405nmFeatures•Operation temperature: •Optical output power: •Vi•Low operating voltage: •Package: •Single•TE mode oscillationOutlineφ5.6–0.025+01.0±0.4-0+0.1122.3±0.2φ4.1±0.3φ3.55±0.11.2±0.16.5±1.0132Data Sheet40071MG (PREnm/300mWViolet Laser DiodeFeaturesApplicationOperation temperature: -0~+70°C Optical output power: 300mW (CW) Violet Lasing: 405nm Typ. Low operating voltage: 5.9V Typ. Package: φ5.6mm Singletransverse mode TE mode oscillation•Bio & Medical•Measurement•3D PrinterOutlineInternal Circuit* Monitor PD for initial checking purpose only(Unit: mm) ・HL40071MGPD120.025±0.1(0.4)(90o)φ1.6±0.23φ2.0±0.20.25Glass1.30Emitting Point3-φ0.45±0.13(PRELIMINALY)Laser DiodeApplicationBio & MedicalMeasurement3D PrinterInternal Circuit* Monitor PD for initial checking purpose onlyHL40071MGLD23(flange)
image/svg+xmlData Sheet HL40071MG Rev1. Jul. 19. 2017www.ushio-optosemi.com Absolute Maximum Ratings (Tc=25°C) Item Symbol Ratings Unit Optical output power (0 ~ +25°C) Po (0 ~ +25°C) 360 mW LD Reverse Voltage VR(LD) 2 V PD Reverse Voltage * VR(PD) 20 V Operating Temperature Topr 0 ~ +70 °C Storage Temperature Tstg -40 ~ +85 °C * Monitor PD for initial checking purpose only Optical and Electrical Characteristics (Tc=25°C) Parameter Symbol Min Typ Max Unit Test Condition Threshold current Ith – 53 70 mA – Operating current Iop – 280 300 mA Po=300mW Operating voltage Vop – 5.9 6.3 V Po=300mW Beam divergence Parallel to the junction θ// 4 5.5 8 o Po=300mW, FWHM Beam divergence Perpendicular to the junction θ⊥14 15 17 o Po=300mW, FWHM Lasing Wavelength λp 400 405 410 nm Po=300mW Monitor Current * Is – (0.09) – mA Po=300mW, VR(PD)=5V * Monitor PD for initial checking purpose only
image/svg+xmlData Sheet HL40071MG Rev1. Jul. 19. 2017www.ushio-optosemi.com Cautions 1.USHIO OPTO SEMICONDUCTORS,INC.(UOS) neither warrants nor grants licenses of any our lights or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document, UOS bears no responsibility for problems that may arise with third party’s right, including intellectual property rights, in connection with use of the information contained in this document. 2.Products and product specifications may be subject to change without notice. Confirm that you have received the latest product standards or specifications before final design, purchase or use. 3.UOS makes every attempt to ensure that its products are of high quality and reliability. However, contact our sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, combustion control, transportation, traffic safety equipment or medical equipment for life support. 4.Design your application so that the products is used within the ranges guaranteed by UOS. particularly for maximum rating, operating supply voltage range, heat radiation characteristics, installation conditions and other characteristics. UOS. bears no responsibility for failure or damage when used beyond the guaranteed ranges. Even within the guaranteed ranges, consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so that the equipment incorporating UOS product does not cause bodily injury, fire or other consequential damage due to operation of the UOS product. 5.This product is not designed to be radiation resistant. 6.No one is permitted to reproduce or duplicate, in any form, the whole or part of this document without written approval from UOS. 7.Contact our sales office for any questions regarding this document or UOS products. 1.The laser light is harmful to human body especially to eye no matter what directly or indirectly. The laser beam shall be observed or adjusted through infrared camera or equivalent. 2.This product (without violet laser diode) contains gallium arsenide (GaAs), which may seriously endanger your health even at very low doses. Please avoid treatment which may create GaAs powder or gas, such as disassembly or performing chemical experiments, when you handle the product. When disposing of the product, please follow the laws of your country and separate it from other waste such as industrial waste and household garbage. Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by UOS before they become applicable to any particular order or contract. In accordance with the UOS policy of continuous improvement specifications may change without notice. Further details are available from any UOS sales representative. Caution – use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
  • Home
  • News
  • Calculators
  • Datasheets
  • Laser Safety
  • Pointers
  • Industrial
  • Lab Lasers
  • Optics
  • Physics

© 2025 405nm.com

Contact Us

Sitemap

Scroll to top
  • Home
  • News
  • Calculators
  • Datasheets
  • Laser Safety
  • Pointers
  • Industrial
  • Lab Lasers
  • Optics
  • Physics
Search