Sharp GH0652AA2G Datasheet

image/svg+xmlsharp LDA-E4-5-16-AGH0652AA2GLaser DiodeLaser DiodeSep 1, 2016SPECIFICATIONShttp://www.sharp-world.com/products/device/NoticeContents in this technical document be changed without any notice due to the product modification.In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in wquipment using any SHARP devices shown in catalogs, data books, etc.LIGHTING BUSINESS UNITELECTRONIC COMPONENTS AND DEVICES BUSHARP CORPORATIONDownloaded fromArrow.com.
image/svg+xml1. These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp").   Please do not reproduce or cause anyone to reproduce them without Sharp’s consent.2. When using this product, please observe the absolute maximum ratings and the instructions for use outlined   in these specification sheets, as well as the precautions mentioned below.   Sharp assumes no responsibility for any damage resulting from use of the product which   does not comply with the absolute maximum ratings and the instructions included in these   specification sheets, and the precautions mentioned below. (Precautions)   (1) Please do verify the validity of this part after assembling it in customerʼs products, when     customer wants to make catalogue and instruction manual based on the specification sheet     of this part.(2) This product is designed for use in the following application areas ;      · OA equipment Audio visual equipment · Home appliances      · Telecommunication equipment (Terminal) · Measuring equipment      · Tooling machines · Computers      If the use of the product in the above application areas is for equipment listed in paragraphs      (3) or (4), please be sure to observe the precautions given in those respective paragraphs. (3) Appropriate measures, such as fail-safe design and redundant design consideringthe safety design of the overall system and equipment, should be taken to ensure reliability and safety when this product is used for equipment which demands high reliability and safety in function and precision, such as ;      · Transportation control and safety equipment (aircraft, train, automobile etc.)      · Traffic signals · Gas leakage sensor breakers · Rescue and security equipment      · Other safety equipment(4) Please do not use this product for equipment which require extremely high reliability and safety in function and precision, such as ;      · Space equipment · Telecommunication equipment (for trunk lines)      · Nuclear power control equipment · Medical equipment(5) Please contact and consult with a Sharp sales representative if four are any questions     regarding interpretation of the above four paragraphs.3. Please contact and consult with a Sharp sales representative for any questions about this product.Model No. GH0652AA2Gsharp LDA-E4-5-16-A1http://www.sharp-world.com/products/device/“Contents in this technical document be changed without any notice due to the product modification.”Downloaded fromArrow.com.Downloaded fromArrow.com.
image/svg+xmlOperating and handling precautions(1) This product has its life. The product life which is described in "Reliability" should be taken into account when using it.(2) This product will be damaged by electrostatic discharge(ESD). Following precautions should be taken to avoid ESD damage.⇒ Workers, workbenches and other equipment should always be grounded. Workers should always wearan antistatic wrist strap and an antistatic smock on them.⇒ When handling this product, workers should always wear antistatic gloves or finger covers. ⇒ A stable DC power supply which is free from electrical transients should always be used when operating this product. A slow starter circuit should always be inserted between the power supply and this product in order to protect it from DC power surges.⇒ Optical power output of this product should be set with a highly reliable and high quality variable resistance. ⇒ This product should always be connected to the driving circuit by soldering directly or through highly reliable connectors.⇒ While this product is being operated, be sure to avoid touching the driving circuit or the terminals of this product with electrical probes from a synchroscope or a voltmeter.⇒ An antistatic package should be used when storing this product. ⇒ This product should be processed in the rooms where relative humidity is kept at 50-70%RH.(3)This product doesn’t do the design that intends use in the following, special environment.   Please use it after confirming the performance and reliability, etc. enough in your company   before use in the following special environment. ⇒Use in place where a lot of moisture, be dewys, sea breezes, or causticity gases (Cl, H2S, NH3, SO2, and NOX, etc.) exist. ⇒Use under direct sunshine, in out-of-door exposure, or in dust. ⇒Use in atmosphere such as water, oil, drug solutions, or organic solvents. ⇒Use in environment with strong static electricity or electromagnetic radiation. ⇒Use in state installed near generation of heat parts or in state to arrange combustiblenear this product.(4)Because the adhesion of garbage and dust to the window glass might disarrange an optical  characteristic of this product, maintain the work room to cleanness so as not generate dust, please. (5)In this Product,generation of heat happens in the laser chip because of operating.  The case temperature rises by this generation of heat. Because the rise of  the case temperature becomes a factor to shorten the lifetime of this product,  a sufficient heat sink should be attached to this product when operating so that its case  temperature is to be maintained at the same level as that of the surrounding. (6) Even if the drive current supply has an automatic power control (APC), automatic current control (ACC), or both, be sure to monitor the optical power output with an optical power meter while setting it. Never estimate the optical power output only from the drive current because it is likely to be decreased by temperature rise (7)When dirt adheres to the window glass of this product, please wipe lightly with  of the surrounding.  the cotton bud that adheres the ethanol.(8)The window glass cracks easily because it is thin. Therefore, please avoid putting the   load on the cap, for example clumping, tightens, or fixing to the treatment device hard. (9) Since laser beam from this product will be harmful to the human eyes, the following precautions should be taken.⇒ When this product is being operated, the emitting surface of a chip should not be viewed either directly or through a lens, microscope or optical fibers.⇒ When operating this product, wear safety glasses.(10) When soldering this product,heat lead pins only using a soldering iron in short time. Avoid heat the whole package using pre-heat or reflow soldering.Model No. GH0652AA2Gsharp LDA-E4-5-16-A2http://www.sharp-world.com/products/device/“Contents in this technical document be changed without any notice due to the product modification.”Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.
image/svg+xml0±0.080±0.08Emission pointCenter of the imaginary circlewhich goes through the threepoint around the stemEnlarged drawing around the emission pointXY21 Laser DiodeTerminal connectionsNote 1) Dimension of the bottom of leads.Note 2) These dimensions are valid only in the range of 0 ~ 0.6mm below from the reference plane. Note 3) These dimensions are defined from the imaginary circle which goes through the threepoints around the stem to the bottom of cut off parts.■ Outline dimensions and Terminal connectionsReference planeφ1.0 MIN.φ3.55 ±0.1φ4.4 MAX.0.25 ±0.030.5MIN.Z①,②C 0.1MAX.0.1MAX.Note 3)0.4 ±0.1Note 1)  φ2.0 Note 2)1 ±0.15Note 2)90°±212XYEmission pointNote 3)0.4 ±0.1Note 2)φ5.6 +0.00 -0.032.65 ±0.083.35 ±0.51.2 ±0.16.5 ±0.52 -φ0.45 ±0.1Mass of the product : 0.32g (reference value)Model No. GH0652AA2Gsharp LDA-E4-5-16-A3http://www.sharp-world.com/products/device/“Contents in this technical document be changed without any notice due to the product modification.”Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.
image/svg+xml■ Ratings and CharacteristicsAbsolute Maximum Ratings(Note 1)Tc : Case temperature(Note 2)Soldering temperature means soldering iron tip temperature(The power 30W) while soldering.        Soldering position is 1.6mm apart from bottom edge of the case.(Immersion time: ≦3s)IthVopλpΘ”ΘTPo = 180 mWMIN.TBDTBD3.06551218+5mAmAVnm°°IopΔΘ”ΔΘTηdTYP.MAX.mW/mA°°+5–-552002.6650712.5––1.25--5-584645––I(180mW)-I(30mW)150mW(Tc=25℃(Note 1))ParameterThreshold currentOperating currentOperating voltageWavelength (Note 4)Half Intensity Angle(Parallel)(Note 2,3)Half Intensity Angle(Perpendicular)(Note 2,3)Misalignment angle (Parallel) (Note 3)Misalignment angle (Perpendicular) (Note 3)Differential efficiencySymbolValueUnit––(Note 1)Initial value, Continuous Wave Operation(Note 2)Angle of 50% peak intensity (Full angle at half-maximum)(Note 3)Parallel to the junction plane(X-Z plane)(Note 4)It is based on method for measurement of light spectrum analyzer Q8344Amade by Advantest Corp. of Sharp Corp. property. Model No. GH0652AA2Gsharp LDA-E4-5-16-A4http://www.sharp-world.com/products/device/“Contents in this technical document be changed without any notice due to the product modification.”Optical power output (-20℃≦Tc≦40℃)PoVrlTop(c)TstgTsld902-20 ~ +85-40 ~ +105350mWV℃℃℃Optical power output (40℃<Tc≦70℃)Optical power output (70℃<Tc≦85℃)Reverse voltageOperating temperature (Case temperature) Storage temperatureSoldering temperature (Note 2)PoPo140200mWmW(Note1)Parameter SymbolValueUnitDownloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.
image/svg+xmlhttp://www.sharp-world.com/products/device/(Notice)・In the absence of confirmation by device technical sheets. SHARP takes no responsibility for any defects that may  occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain  the latest device technical sheets before using any SHARP device.・technicals are subject to change without notice for improvement.sharp LDA-E4-5-16-ADownloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.Downloaded fromArrow.com.
  • Home
  • News
  • Calculators
  • Datasheets
  • Laser Safety
  • Pointers
  • Industrial
  • Lab Lasers
  • Optics
  • Physics

© 2025 405nm.com

Contact Us

Sitemap

Scroll to top
  • Home
  • News
  • Calculators
  • Datasheets
  • Laser Safety
  • Pointers
  • Industrial
  • Lab Lasers
  • Optics
  • Physics
Search