ROHM RLD78NZM7 Datasheet
RLD78NZM700A008: Laser Diode
image/svg+xml
1/8
780nm Invisible Single Mode Laser Diode
RLD78NZM7
Datasheet
https://www.rohm.com/
© 2019 ROHM Co., Ltd. All rights reserved.
201
9
.
7
–
Rev.0
0
8
Application
Laser printer
Sensor
Etc.
Merit
Single mode
Φ
5.6 metal stem
Absolute Maximum Ratings (Tc=25°C)
Parameter Symbol Ratings Unit
Optical output Po 20 mW
Reverse voltage
LD Vr 2 V
PIN PD Vr(PD) 20 V
Operating temp. Top -10 to 60 °C
Storage temp. Tstg -40 to 85 °C
Characteristics (Tc=25°C)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Threshold current Ith
-
7 11 20 mA
Operating current Iop Po=15mW 21 33 63 mA
Operating voltage Vop Po=15mW 1.7 1.8 2.2 V
Output efficiency
η
5mW/(I(15mW)-I(10mW)) 0.35 0.65 1.05 W/A
Monitor current Im Po=15mW, Vr(PD)=15V 0.5 0.9 1.8 mA
Beam divergence
θ
//
Po=15mW
6.0 8.5 12.0 deg.
θ
⊥
20 24 28 deg.
Beam tolerance
⊿
θ
//
Po=15mW
-3 0 +3 deg.
⊿
θ
⊥
-4 0 +4 deg.
Emission point
accuracy
⊿
XYZ
-
-100 0 +100
µ
m
Lasing wavelength
λ
Po=15mW 775 792 800 nm
Astigmatic difference
As NA=0.55, Po=3.5mW
-
2 10
µ
m
Caution:
θ
⊥
and
θ
// are defined as full width at half maximum.
Operation temperature is regulated by case temperature; Tc
Outline view
image/svg+xml
RLD78NZM7
2/8
Datasheet
https://www.rohm.com/
© 2019 ROHM Co., Ltd. All rights reserved.
201
9
.
7
–
Rev.0
0
8
Electrical Characteristics
Optical
Optical Optical
Optical
Characteristics
CharacteristicsCharacteristics
Characteristics
* This data is made from the result of having measured the sample extracted at random. Therefore, it is not what showed the
ability of the whole product.
0
1
2
3
4
5
0
2
4
6
8
10
12
14
16
18
20
0102030405060
Vf [V]
P
o
[mW]
I
f
[mA]
I-L
I-V
25℃
40℃
50℃
60℃
0
2
4
6
8
10
12
14
16
18
20
00.511.5
Po [mW]
Im [mA]
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
-60-40-200204060
Intensity
FFP [deg.]
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
785790795800805
Intensity
λ [nm]
25
℃
40
℃
50
℃
60
℃
image/svg+xml
RLD78NZM7
3/8
Datasheet
https://www.rohm.com/
© 2019 ROHM Co., Ltd. All rights reserved.
201
9
.
7
–
Rev.0
0
8
Dimensions
Equivalent Circuit Diagram
image/svg+xml
RLD78NZM7
4/8
Datasheet
https://www.rohm.com/
© 2019 ROHM Co., Ltd. All rights reserved.
201
9
.
7
–
Rev.0
0
8
Specifications (Precautions and Prohibitions)
●
Precautions on using ROHM Products
1) Our Products are designed and manufactured for application in ordinary electronic equipment (such as AV equipment,
OA equipment, telecommunication equipment, home electronics appliances, amusement equipment, etc.). If you intend
to use our Products in devices requiring extremely high reliability (such as medical equipment, transport equipment,
traffic equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car accessories,
safety devices, etc.) and whose malfunction or failure may cause loss of human life, bodily injury or serious damage to
property (“Special Applications”), please consult with the ROHM sales representative in advance. Unless otherwise
agreed in writing by ROHM in advance, ROHM shall not be in any way responsible or liable for any damages, expenses
or losses incurred by you or third parties arising from the use of any ROHM’s Products for Specific Applications.
2) ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor products
can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate safety
measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure
or malfunction of our Products may cause. The following are examples of safety measures.
[a] Installation of protection circuits or other protective devices to improve system safety
[b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure
3) Our Products are designed and manufactured for use under standard conditions and not under any special or
extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible
or liable for any damages, expenses or losses arising from the use of any ROHM’s Products under any special or
extraordinary environments or conditions. If you intend to use our Products under any special or extraordinary
environments or conditions (as exemplified below), your independent verification and confirmation of product
performance, reliability, etc, prior to use, must be necessary:
[a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents
[b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust
[c] Use of our Products in places where the Products are exposed to sea winds or corrosive gases, including Cl2, H2S,
NH3, SO2, and NO2
[d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves
[e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items
[f] Sealing or coating our Products with resin or other coating materials
[g] Use of our Products without cleaning residue of flux (even if you use no-clean type fluxes, cleaning residue of flux is
recommended); or Washing our Products by using water or water-soluble cleaning agents for cleaning residue
after soldering
[h] Use of the Products in places subject to dew condensation
4) The Products are not subject to radiation-proof design.
5) Please verify and confirm characteristics of the final or mounted products in using the Products.
6) In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse) is applied,
confirmation of performance characteristics after on-board mounting is strongly recommended.
Avoid applying power exceeding normal rated power; exceeding the power rating under steady-state loading condition
may negatively affect product performance and reliability.
7) De-rate Power Dissipation (Pd) depending on Ambient temperature (Ta). When used in sealed area, confirm the
actual ambient temperature.
8) Confirm that operation temperature is within the specified range described in the product specification.